Fire doors
Fire Door Sizes in Bangladesh: Standard Dimensions, ft–mm Conversion and Handing
Standard fire door sizes for single and double leaf doors, with ft to mm conversion, clear opening vs leaf size and door handing explained for buyers.
Safety Plus technical team · Updated · 8 min read
Standard fire door sizes in the Safety Plus catalogue
Fire doors are made in a tested range of sizes. Within that range a manufacturer can usually build to your exact opening; outside it, the rating may not be supported by test evidence. The Safety Plus catalogue sets out the following ranges.
| Model | Type | Width range (L) | Height (H) | Notes |
|---|---|---|---|---|
| SFD 501 | Single leaf | 750 – 1,200 mm | 2,100 or 2,400 mm | Any size within L1,200 × H2,400 |
| SFD 502 | Double leaf | 1,500 – 2,200 mm | 2,100 or 2,400 mm | Equal or unequal pairs to suit the opening |
| SFD 503 | Storage and hospital | To order | To order | Stainless steel 304 or 316 skins |
| SFD 504 | Louver door | To order | To order | Ventilation openings in the leaf |
| SFD 505 | Shaft door | To order | To order | Access to service shafts and risers |
Single leaf widths are offered in steps of about 100 mm from 750 mm upward, and the standard heights are 2,100 mm and 2,400 mm. All models share a 50 mm door thickness and 1.2 mm skin. For louver and shaft doors, see the louver door and shaft door guide.
When an opening is wider than about 1,200 mm, it normally moves to a double leaf door. That is not just a manufacturing preference: very wide single leaves are heavy, strain hinges and closers, and may fall outside the tested size range.
Converting feet to millimetres (and back)
Architects in Bangladesh often draw in millimetres, while contractors, shops and many buyers talk in feet. The conversion is simple — 1 ft = 304.8 mm and 1 in = 25.4 mm — but the rounding catches people out.
| Nominal size in feet | Exact millimetres | Where it sits in the catalogue range |
|---|---|---|
| 3 ft wide | 914 mm | Single leaf |
| 3 ft 6 in wide | 1,067 mm | Single leaf |
| 4 ft wide | 1,219 mm | Just above the 1,200 mm single leaf maximum — confirm with the supplier |
| 5 ft wide | 1,524 mm | Double leaf range |
| 6 ft wide | 1,829 mm | Double leaf range |
| 7 ft high | 2,134 mm | Slightly above the 2,100 mm standard height |
| 8 ft high | 2,438 mm | Slightly above the 2,400 mm standard height |
And the reverse, for reading metric drawings:
| Metric size | Feet and inches |
|---|---|
| 750 mm | 2 ft 5.5 in |
| 900 mm | 2 ft 11.4 in |
| 1,000 mm | 3 ft 3.4 in |
| 1,200 mm | 3 ft 11.2 in |
| 1,500 mm | 4 ft 11.1 in |
| 1,800 mm | 5 ft 10.9 in |
| 2,100 mm | 6 ft 10.7 in |
| 2,200 mm | 7 ft 2.6 in |
| 2,400 mm | 7 ft 10.5 in |
The lesson: a "7 ft" door and a "2,100 mm" door are not the same. Online listings such as the 3 ft × 7 ft or 4 ft × 8 ft doors use nominal sizes. Before ordering, ask the supplier to confirm the actual frame outside dimensions in millimetres and check them against the opening on site.
Opening, frame, leaf and clear opening: four different numbers
Most sizing disputes come from people using the same word, "door size", for four different measurements.
| Term | What it measures | Who uses it |
|---|---|---|
| Structural opening | The hole in the wall, masonry to masonry | Civil contractor |
| Frame size | Outside dimensions of the steel frame | Door manufacturer, installer |
| Leaf size | The moving door panel itself | Door manufacturer |
| Clear opening | Free passage width when the door is open | Architect, fire safety consultant |
The structural opening must be larger than the frame to leave a fixing and sealing gap; that gap is then closed with grout or fire-stopping material as the installation instructions require. The frame is larger than the leaf because it includes the jambs and head. The leaf is larger than the clear opening because, when the door opens to 90 degrees, the frame stop and the 50 mm thickness of the leaf itself intrude into the passage.
Hardware reduces clear width further. A panic bar projects from the push side of the leaf, and a door that cannot open fully because of a wall return or a door holder position loses more width again. If your fire safety plan or a hospital equipment list sets a minimum clear width, give that number to the supplier and ask them to work out the leaf and frame size from it, rather than the other way round. Building codes, including BNBC 2020, set requirements for exit widths; your consultant should confirm the figure that applies to your occupancy.
Door handing and swing direction
Handing describes which side the hinges are on and which way the door swings. A common convention used by door and hardware suppliers is:
- Stand on the outside of the door (the corridor side, or the side from which you would need a key).
- If the hinges are on your left and the door opens away from you, it is left hand (LH).
- If the hinges are on your right and the door opens away from you, it is right hand (RH).
- If the door opens towards you, add "reverse": LHR or RHR.
Conventions differ between suppliers and countries, so the safest method is a simple plan sketch for each door showing the hinge side and swing arc. Fire doors cannot be re-handed on site the way some timber doors can, because hardware preparation, the closer position and panic device are all set at the factory.
Swing direction is a safety question as well as a fitting one. Exit doors serving larger numbers of people are commonly required to swing in the direction of escape, and doors must not swing into a stair in a way that blocks the escape width. Confirm the direction with your consultant for every door on an escape route.
For double doors, also state which leaf is the active leaf (the one people normally push) and which is inactive. Pairs need a coordinator so the inactive leaf closes first, and an astragal to cover the meeting edges.
Sizing for hospitals, warehouses and plant rooms
The right size depends on what passes through the door, not just on people.
- Hospitals and clinics. Bed and trolley routes need generous clear widths, which often pushes corridors and wards to double leaf or unequal pair doors. The stainless steel SFD 503 model is designed for hospital and storage use. See the hospitals and healthcare page for related products.
- Warehouses and factories. Pallet trucks and material trolleys need clear width plus clearance for handles and loads. Check trolley widths before fixing the opening.
- Plant rooms and electrical rooms. Doors must pass the largest piece of equipment that will ever be installed or replaced, such as a transformer, switchboard section or pump. A door sized only for people may force a wall to be broken later.
- Stair cores. Doors must not reduce the stair landing width needed for escape. Leaf size and swing must be planned with the stair layout.
When in doubt, size for the largest item and the escape requirement, then choose single or double leaf to fit.
Vision panels, colour and other details to fix at the sizing stage
A few details are best decided together with the size because they are built into the leaf at the factory:
- Vision panel. The Safety Plus catalogue uses 6 mm tempered vision glass with a standard exposed area of 450 × 150 mm. Larger or differently placed panels must stay within what the door's test evidence covers.
- Hardware preparation. Closer, panic device, lock and hinge positions are cut and reinforced during manufacture, so choose the fire door hardware set before the order is placed.
- Colour. Safety Plus offers the full RAL colour range, subject to quantity.
- Threshold and undercut. If a floor finish such as tiles or epoxy will be added later, tell the supplier the finished floor level so the bottom gap is correct after the floor is laid.
Once these are fixed, send the schedule through the request a quote page, or review the fire rated doors range. For writing the full tender description, use the fire rated door specification checklist.
Frequently asked questions
What is the standard size of a single fire door?
In the Safety Plus catalogue, single leaf fire doors range from 750 mm to 1,200 mm wide at 2,100 mm or 2,400 mm high. In feet, many buyers ask for 3 ft × 7 ft, which is about 914 × 2,134 mm.
When should I choose a double leaf fire door?
Choose a double leaf door when the opening is wider than about 1,200 mm or when equipment, beds or trolleys need more clear width. The Safety Plus double leaf range runs from 1,500 mm to 2,200 mm wide.
Is the quoted door size the wall opening or the door leaf?
It varies by supplier, which is why you should always ask. State clearly whether your figure is the structural opening, frame size, leaf size or required clear opening.
How thick is a fire door?
Safety Plus fire rated doors are 50 mm thick with 1.2 mm steel skins. Thickness matters for sizing because the leaf reduces the clear opening when open at 90 degrees.
Can a fire door be cut down on site to fit the opening?
No. Cutting a fire door leaf or frame on site can void its rating. Measure the opening accurately and order the correct size from the manufacturer.